Skip to article frontmatterSkip to article content
Site not loading correctly?

This may be due to an incorrect BASE_URL configuration. See the MyST Documentation for reference.

Hotfix failure

Incident report November 3 2026 - Hotfix failure

Summary

A hotfix was applied to multiple clusters with the skip-deploy label applied. The fix was insufficiently validated with a manual deploy against the nasa-ghg-hub cluster the evening before, and subsequently applied in error across the network the morning after by an engineer. A decision was made to apply the skip-deploy label to avoid known CI/CD issues with the CloudBank cluster and, ironically, prevent disturbing workshop events scheduled for that day.

Impact on community

Support tickets were raised by two communities, one of which was holding a workshop event:

Contributing factors

The nasa-ghg-hub image was different from the basehub image, so the hotfix for this cluster did not apply to other clusters

The scheduled events prompted a decision to expedite deployment of the hotfix before the events started

However, network-wide CI/CD deployment was considered too risky just before an event, so the skip-deploy and manual approach was taken

Ironically, the deployment strategy taken above ended up causing outages across multiple hubs

What went well

What could be improved

This occurred when we knew workshop events were scheduled. Should we automatically “freeze” non-workshop-related configuration changes on hubs with events at least 24 hours before an event?

There are varying levels of mistrust in the network-wide CI/CD deployment pipeline, which can lead to inconsistent expectations between desired config and current state. Can we make some fundamental improvements to the CI/CD strategy so that deployments become trustworthy again?

The hotfix was applied to the usage quotas application, running as an internal JupyterHub service. This was a known weakness, and work to separate concerns was in progress.

Timeline (UTC)

TimestampMarkerNotes
09:40DetectHotfix applied by Engineer 1.
10:38DetectJupyterHub URL availability alert fired and noticed by Engineer 2.
10:49DiagnosisOutage identified and PR to revert hotfix applied by Engineer 2. Infra manually stabilised by Engineer 1 with helm rollback.
12:20Key momentIncident declared over.
13:06RepairHotfix removed from infra by Engineer 1.

Action items